ruskin dampers. Commercial Dampers. ruskin dampers

 
Commercial Dampersruskin dampers  Refer to the UL approved installation instructions for specific requirements

Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. 2) wall thickness with 12 gage (2. The blades are the same thickness throughout the shape, optimizing the R-Value rating. The CD60CE in 316 stainless steel construction offers superior corrosion resistance and. Page 1 INSTALLATION SUPPLEMENTS Horizontal Installation – 90"w x 91"h (2286 x 2311) or 114"w x 38"h. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. 3. 5 illustrates a plenum mounted damper. Access doors provide an easy means of reaching damper components inside the ductwork. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. lbs. Access Doors. Louvers & Architectural. Multi-section dampers typically use jackshafts to link sections together. W. Out of wall “OW” fire dampers are designed so that the leading edge of the damper frame can be up to 8" (203) out of the wall, partition or masonry floor. 4 inches w. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). The CFDR2 is a UL555C Classified Round Ceiling Fire Damper. ft. 2. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec - ommended maximums. DAMPER SIZES Understanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. Ruskin. It features: Corrosion resistant backdraft protection from its stainless steel construction. Ruskin’s Information is not a. A 1" (25) diameter jackshaft is normally used. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. Dampers furnished actual size. Life Safety Dampers. Pressure Relief Doors. (2) ‘S. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowThe FSD60V Combination Fire/Smoke Damper is both UL555 and UL555S Classified. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. Damper shall be in all respects equivalent to Ruskin BD6. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. MAXIMUM SIZE Single section Vertical Installation DIBD2 - 32"w x 36"h (813 x 914). effort to avoid misapplication. (0. The damper is rated for maximum velocity of 2,000 fpm (10. Single Blades. Auto-Balancing. Industrial Fiberglass Louvers. g. The CD50 was the first AMCA-licensed low leakage damper and bears the AMCA Air Leakage Seal. Readily connects to round spiral or flexible ductwork. Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. g. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. The Ruskin optional firestopping installation is one of our latest installation instruction supplements we offer. It also features: Frame corners that are internally braced to reduce racking. Ruskin Literature. The CD51 is structurally designed for velocities to 2000 fpm. FILES (0) Share this page: Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. 1. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. Damper – Ruskin fire or fire/leakage rated damper in minimum 20 gage (1. 3 (damper installed with duct upstream and downstream). It features a galvanized steel frame, single skin blades, and a variety of actuator options. The foregoing limited warranty does not apply to (i) consumable products and components (e. Life Safety Products. Static only damper labels are not permissible. Pressure Relief Doors. 4 inches w. Concealed linkage out of the airstream for low maintenance and reduced air turbulence. /Class III, V-Groove Blade,. (1. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. Greaves Rd. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. Actuators enable a damper to operate with controlled positioning throughout the stroke of the damper. Stainless Steel Construction See model (D)IBD2SS. Note: Multiple section dampers are not intended to be structural supports. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. Dynamic fire dampers shall be Ruskin multiple model DFD35. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. Must be installed in the factory. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. See “Combination Fire Smoke Damper Multiple Section Detail” specPerfect for a Wide Variety of Applications. Ruskin offers blast suppression dampers which are custom designed to each application. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. g. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. The CD40 Series has 6" wide V-grooveThe PFL is a UL Classified heat responsive device used in conjunction with Ruskin fire/smoke dampers. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. The damper is rated for5 82w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Static pressure and CFM are corrected to. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Corrosion. The CD60 offers sturdy, steel construction with an interlocking frame design, enabling it to lock together without bolts, screws, or rivets that could shake loose. Learn about their history, products,. Spec AIRFLOW-IQ-0121 STATD SPTS R ST T TT T R T. EFL or PFL heat-actuated devices that permit closed closure through the actuator and are automatic remote resettable after test, smoke detection, or power. The CFD7T-SR is a UL Classified Ceiling Fire Damper listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548, P572, and H502. Johnson Controls offers a broad range of HVAC dampers and louvers engineered to fit your unique application and size requirements. 21. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Dampers above 18" (457) – 10 gage steel (3. Masonry/Wall or Floor: #10 self-tapping concrete screws. Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. Damper frames Dampers shall be constructed with premium vinyl ester resins suitable for specified. Model ‘G’ curtain fire dampers are offset. Carbon steel construction. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. Maximum rating of 2,000 fpm and 4" w. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. The ratings shown are based on tests and procedures performed in accordance with AMCA Publica-tion 511 and comply with the requirements of the AMCA Certified Ratings Program. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. 3. To provide even greater control of dampers in HVAC systems, Ruskin also. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. g. V Groove & Single Blades. INSTALLATION Install with frame square without twisting or racking. Axles shall be square or hexagonal positively locked into the damper blade. Automatic Balancing Dampers. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. Counter Balanced Backdraft Damper. Ruskin CD30AF1/CD30AF2 con-trol dampers. angles together at corners of dampers. Ceiling Fire Dampers UL Classified Radiation Dampers Underwriters Laboratories has classified hundreds of specific Floor/Ceiling (F/Cs) and Roof/ Ceiling (R/Cs) and established Fire Resistance Ratings for each design ranging from 1/2 to 5 hours. 8) steel. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin continues to provide the industry with the most UL approved field installation solutions for fire and fire/smoke dampers. 2 m/s) and 4” w. Following system stabilization, normal counter-balance operation will continue. Maximum rating of 4,000 fpm and 4" w. GENERAL INSTALLATION NOTES 1. Damper frames Dampers shall be constructed with premium vinyl ester resins suitable for. Ruskin model CD60 offers HVAC design engineers an ultra-low leak high performance damper which provides: • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Insulating Control Dampers. 24VAC modulating actuators (spring return or fail-in-place) can. Commercial Control Dampers; Sound Control; Industrial Control Dampers; Software. Quick Select. at corners of dampers. 2. ©Ruskin October 2007 ® Spec FSD60-C-1007/Replaces FSD60/36-C-1206 APPLICATION The FSD60-C is two dampers in one. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. Opposed blade dampers must be operated from a power blade on the. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. For proper operation, damper must be installed square and free from racking. Noise Control. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. . Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Actuators and Damper Accessories. The factory mounted fast-acting 8-second spring open actuatorprovides optimal performance and reliability. It also features: Frame corners that are internally braced to reduce racking. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/Steel Stud Wall: #10 screws. Ruskin (Thailand) Co. Axles shall be square or hexagonal positively locked into the damper blade. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. g. Excellent weather protection when installed in. For some applications, it is essential that thermal conductivity be kept at a minimum. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. Masonry/Wall or Floor: #10 self-tapping concrete screws. 5. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. So turn “on” to energy savings while your building is“off” and let Ruskin start saving you money today. It features: Vertical blades. Industrial FAQs. Ruskin Literature. • Sealing durability in. Models CD36, CD35, IL35, CD40 and CD403, 4". of damper with minimum of 20 in. O. The CFDR5 is a Round, UL555C Classified Ceiling Fire Damper. Leakage information based on pressure differential of 1" w. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. rectangular, airfoil, class IA leakage, heavy duty, 6000 FPM, 13" w. Dampers may tolerate higher pressures and velocities than those listed here. of damper with minimum of 20 in. 8955DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. g. (2) ‘E’ Clips 3. 350° Horizontal FSD36LP 36"x 14" 4"w. 125" (3. The CD51 can be utilized in systems calling for less than 10 cfm/sq. Standard features vary by model to make application selection straightforward. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. The TS150 is an optional device which can be ordered with electric actuators or pneumatic actuators and EP (electro/pneumatic) switches. a. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. b. Aluminum construction. Learn how to select the best damper for your system and achieve optimal air. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). This folder features all of the latest literature that Ruskin has produced, available in. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for 2” x10” or 2” x 12” wood joist assemblies (Ref. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. used in conjunction with Ruskin fire/smoke dampers. Ruskin fire dampers may be installed using Ruskin PFMA. It features: A static pressure control option, which enables field adjustment to maintain static pressures ranging up to . It features: UL555S Class I leakage class. Ruskin May 2020 Page 1 Models CFD(R)2, CFD(R)3, CFD(R)3. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. Galvanized Steel V-Groove Blades. angles together at corners of dampers. Welcome to Ruskin Rooftop Systems 972. Damper shall be, in all respects, equivalent to Ruskin model BD2A2. 765. CDRS82 ROUND CONTROL DAMPER Spec CDRS82-102/Replaces CDRS82-193 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 75" w. Commercial Dampers. Rusin anuary 2021 Replaces Spec AIRFLOW-IQ-01 Pae 4 High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. The commercial dampers provide low pressure openings with exceptional pressure drop performance, while the industrial line includes heavier gauge materials to. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. Ruskin August 2020 Page5 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Dampers shall be Ruskin model FSDR25. Greaves Rd. • Damper Styles A, BC, WC, WR and WO • 4000 FPM Max. 1. lbs. 3. If the actuator must be mounted on top or bottom, select the FSD60V. AXLE All axles to extend 6" (152) beyond damper frame. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. The TS150 must be installed at the factory and cannot be added in the field. (2) 1/4-20 Nuts 2. Their line includes duct smoke detectors, flanged breakaway connections, fire damper angles, auxiliary switches, and more. The CBDR82 damper blade willRuskin is pleased to announce the availability of Revit® 3-D files of select products. Greaves Rd. The results show that Ruskin’s CBS8BL dramatically reduces the blast impulse thus protec Ruskin blast damper charts below highlight results of independent third party lab testing of model CBS8BL to peak reflective pre B Impl ( ows ra m Ope nDu ct) Blast Impulse (Downstream Damper)of damper with minimum of 20 in. Control dampers shall be produced in an ISO9001 certified factory. • Fire smoke dampers larger than single section may require multiple actuators. Pressure limitations shown above allow maximum blade deflection of 1/180 of span on 60" (1524) damper widths. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. 3 sq. g. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD50-CE. Linkage is concealed in the frame out of the airstream for low maintenance and reduced. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Dynamic fire dampers shall be Ruskin model DFD60-3. Zone Control. These combination fire and smoke dampers are designed for installation with the blades running horizontally. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. Dampers above 40" (1016) – 10 gage with retainer ring. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. 761. Dynamic fire dampers shall be Ruskin multiple model DFD60. Life Safety » Combination Fire/Smoke Dampers 1. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. 56 psi and 38. Dampers Corridor Dampers Fire Dampers Smoke Dampers Ruskin® 3900 Dr. > Case Studies. Enter the Pressure Drop Chart at the determined area factorRuskin April 2021 Page 3 DAMPER SLEEVE DIMENSIONAL DATA The drawings show the position of the damper mounted in the factory sleeve. a. g. The Model IBDT is a thinline fire damper that can be installed vertically in walls and partitions or horizontally in masonry floors with fire resistance ratings of less than 3 hours. Fiberglass Series round backdraft dampers. Learn more about the features, specifications and dimensions of the PVC12 damper from Ruskin, the leading manufacturer of air control. DAMPER SIZESUnderstanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. 25" w. Galvanized Steel Airfoil Blades. Determine the airflow in CFM. It is a one hour fire rated, UL labeled Corridor Damper and a 11/2 hour fire rated, Leakage Class 1, UL labeled Combination Fire Smoke Damper. Ruskin® A 0 Page 1 CD60CE Critical Environment High performance 316 stainless steel airfoil blade damper AMCA Class IA Leakage Rated The High-Performing Ruskin Model CD60CE is designed to control and regulate air movement in medium to high velocity and pressure HVAC Systems. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Louver blades are . Refer to the UL approved installation instructions for specific requirements. STATIC PRESSURE IN IN. 7476 Fax: 816. The FSDR25C is a round tunnel corridor fire/smoke damper with UL555 Classification as a 1 ½ hour rated fire damper and a Leakage Class I UL555S Smoke Damper. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Ruskin Literature. Unequal section sizes. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. See “Smoke Damper Multiple Section Detail” spec sheet for details. Higher velocities are not recommended for outside air openings, due to water penetration concerns. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. The maximum opening. Consult Ruskin or your Ruskin representative when damper is to be. Ruskin UL listed solutions are available. Get free shipping on orders over $999!%PDF-1. pressure) for 15 minutes. Each has added features that enable them to meet all high temperature, high pressure. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. The damper ships with a factory mounted and commissioned 24 VAC, spring return actuator set to power closed and spring or "fail" open. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. to. (Consult for electronic version of this “Quick” spec as well as for complete 3- part CSI MasterFormat Specifications) Document Title Limited Warranty Document LINKS TO IMPORTANT DOCUMENTSFire and Smoke Dampers Ruskin actionair ES Series Operating And Maintenance Manual. Example: Maximum design total pressure of 8. The unit has encapsulated iris segmented blades and integral air pressure taps for great flow control and validation. angles together at corners of dampers. Axles that positively lock to blades without screws or welds. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. com W: AUTHORITY IN AIR CONTROL Ruskin delivers the most accurate and innovative solutions for data centers. Dampers For More Information: Manufacturer's Site. of damper with minimum of 20 in. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. COMMERCIAL CONTROL, MANUAL, AND. at 4" w. H. 2. 7 %âãÏÓ 69 0 obj > endobj xref 69 77 0000000016 00000 n 0000002434 00000 n 0000002561 00000 n 0000004375 00000 n 0000004685 00000 n 0000005201 00000 n 0000005701 00000 n 0000006313 00000 n 0000006746 00000 n 0000007307 00000 n 0000007930 00000 n 0000007966 00000 n 0000008506 00000 n 0000008619 00000 n. Higher velocities are not recommended for outside air openings, due to water penetration concerns. Marketing Literature; Case Studies;. When used in fan discharge applications, damper should bethe damper frame. The IBDT carries a 1 1/2 hour UL fire damper label and is classified as a static damper for use in HVAC systems that shut down during a fire. Higher velocities are not recommended for outside air openings, due to water penetration concerns. cheng@jci. Brand: Ruskin SKU: CDR92. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. 00. Damper shall be Ruskin model BTR82. Greaves Rd. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. For the name and address of your Ruskin Representative, call (816) 761-7476, or visit our web site at Ruskin can engineer and install pneumatic, electric or manual type actuation to best meet your specifications. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. Our History. L501). Mounting Angle Fasteners Sleeve: #10 bo lts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. GRANDVIEW, Mo. pivot pins. Specifier Select Option Dampers shall be equipped with factory installed damper. Axles that positively lock to blades without screws or welds. g. Each fire damper shall be labeled for use in dynamic systems. CFDR7T - 2"x4" Truss Assemblies (Ref. Ruskin Literature. Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. Commercial Control Damper CD60. The airfoil blades are designed for HVAC systems with velocity and pressures up to 4,000 fpm and 8" w. 025” thick formed aluminum with concealed blade linkage, synthetic bearings. ft. Press and Drag to Scroll. Maximum velocity of 4,000 fpm. dampers. High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. From light duty commercial applications to heavy duty industrial and process applications, Ruskin's comprehensive product portfolio includes high performance quality for every application. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. Maximum velocity for V-Groove blade 2000 FPM and Airfoil blades 3000 FPM. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. 247. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. Damper Width “A” Dimension in inches (mm)Round Control Damper Class 1A Leakage The CDRS25 “true round” control damper is designed for low to medium pressure and. for dampers up to 6 sq. 0) sleeve. Warranty claims under this Limited Warranty should be referred to: Ruskin 3900 Dr. FILES (0) Share this page:Energy Recovery Ventilators. Standard features vary by model to. Complete with 24V modulating actuator and field wired wall mounted, the thermostat gives individual control to office spaces with single or multiple branch ducting. Name. 765. We offer a wide variety of products to mee. The BD6 backdraft damper is ideally suited to heavy duty applications and is AMCA certified for Leakage and Performance. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. II-FSD36-0121/ Replaces II-FSD36-514 ©Ruskin January 2021 ® APPLICATION The FSD35, FSD36 and FSD37 are combination fire and smoke dampers designed to restrict the passage of flame and resist the passage of smoke. From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control damper. They are easy to install, easy to use, and are customizable to the needs of any building automation system. The Damper Test Switch (DTS) is an optional “momentary” push button test switch available on Ruskin fire/smoke dampers. RectangulaR DampeRs CD40, CD50, CD60 SerieS DeSCripTiOn The ruskin CD40, CD50, CD60 parallel and opposed-blade HVAC control dampers are custom made-to-order. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. CFD7T - 2"x4" Truss Assemblies (Ref. The CD40x2 has an 8" frame and aluminum construction. Damper shall be in all respects equivalent to Ruskin BD6. Ruskin® 3900 Dr. 1. Ruskin’s low leak control dampers can save building owners up to $30 per damper 1 annually by providing tight sealing of outside air openings. g. When installed as shown, they provide appropriate protection for air inlet or outlet penetrations in the ceiling membrane of floor/ceiling and roof/ceiling assemblieslabel and is classified as a static damper for use in HVAC systems that shut down during a fire. g. into damper blade and not a secondary operation. NOTES: 1. Figure 5. Fire dampers are UL555 tested and labeled devices installed in ducts and air transfer openings or air distribution systems, designed to close upon the detection of heat. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. upstream of the damper. Ruskin Brands and Locations. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Dampers shall be Ruskin Swartwout Series Model CBDR912. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. • For proper operation, damper must be installed square and free from racking.